Files
crystall-punk-14/Content.IntegrationTests/Tests/Access/AccessReaderTest.cs

113 lines
5.9 KiB
C#
Raw Normal View History

using System.Collections.Generic;
using Content.Shared.Access;
using Content.Shared.Access.Components;
using Content.Shared.Access.Systems;
using Robust.Shared.GameObjects;
using Robust.Shared.Map;
using Robust.Shared.Prototypes;
2022-01-10 18:13:12 -07:00
namespace Content.IntegrationTests.Tests.Access
{
[TestFixture]
[TestOf(typeof(AccessReaderComponent))]
public sealed class AccessReaderTest
{
[TestPrototypes]
private const string Prototypes = @"
- type: entity
id: TestAccessReader
name: access reader
components:
- type: AccessReader
";
[Test]
public async Task TestTags()
{
2023-08-25 02:56:51 +02:00
await using var pair = await PoolManager.GetServerClient();
var server = pair.Server;
var entityManager = server.ResolveDependency<IEntityManager>();
await server.WaitAssertion(() =>
{
var system = entityManager.System<AccessReaderSystem>();
var ent = entityManager.SpawnEntity("TestAccessReader", MapCoordinates.Nullspace);
var reader = new Entity<AccessReaderComponent>(ent, entityManager.GetComponent<AccessReaderComponent>(ent));
// test empty
Assert.Multiple(() =>
{
Add door electronics access configuration menu (#17778) * Add door electronics configuration menu * Use file-scoped namespaces Signed-off-by: c4llv07e <kseandi@gmail.com> * Open door electronics configuration menu only with network configurator Signed-off-by: c4llv07e <kseandi@gmail.com> * Doors will now try to move their AccessReaderComponent to their door electronics when the map is initialized Signed-off-by: c4llv07e <kseandi@gmail.com> * Make the access list in the id card computer a separate control Signed-off-by: c4llv07e <kseandi@gmail.com> * Fix merge conflict Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove DoorElectronics tag Signed-off-by: c4llv07e <kseandi@gmail.com> * Integrate doors with #17927 Signed-off-by: c4llv07e <kseandi@gmail.com> * Move door electornics ui stuff to the right place Signed-off-by: c4llv07e <kseandi@gmail.com> * Some review fixes Signed-off-by: c4llv07e <kseandi@gmail.com> * More fixes Signed-off-by: c4llv07e <kseandi@gmail.com> * review fix Signed-off-by: c4llv07e <kseandi@gmail.com> * move all accesses from airlock prototypes to door electronics Signed-off-by: c4llv07e <kseandi@gmail.com> * rework door electronics config access list Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove Linq from the door electronics user interface * [WIP] Add EntityWhitelist to the activatable ui component Signed-off-by: c4llv07e <kseandi@gmail.com> * Better interaction system Signed-off-by: c4llv07e <kseandi@gmail.com> * Refactor Signed-off-by: c4llv07e <kseandi@gmail.com> * Fix some door electronics not working without AccessReaderComponent Signed-off-by: c4llv07e <kseandi@gmail.com> * Move AccessReaderComponent update code to the AccessReaderSystem Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove unnecesary newlines in the door access prototypes Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove unused variables in access level control Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove unnecessary method from the door electronics configuration menu Signed-off-by: c4llv07e <kseandi@gmail.com> * [WIP] change access type from string to ProtoId<AccessLevelPrototype> Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove unused methods Signed-off-by: c4llv07e <kseandi@gmail.com> * Newline fix Signed-off-by: c4llv07e <kseandi@gmail.com> * Restored to a functional state Signed-off-by: c4llv07e <kseandi@gmail.com> * Fix access configurator not working with door electronics AccessReaderComponent Signed-off-by: c4llv07e <kseandi@gmail.com> * Replace all string access fields with ProtoId Signed-off-by: c4llv07e <kseandi@gmail.com> * move access level control initialization into Populate method Signed-off-by: c4llv07e <kseandi@gmail.com> * Review --------- Signed-off-by: c4llv07e <kseandi@gmail.com> Co-authored-by: metalgearsloth <comedian_vs_clown@hotmail.com>
2024-04-01 09:06:13 +03:00
Assert.That(system.AreAccessTagsAllowed(new List<ProtoId<AccessLevelPrototype>> { "Foo" }, reader), Is.True);
Assert.That(system.AreAccessTagsAllowed(new List<ProtoId<AccessLevelPrototype>> { "Bar" }, reader), Is.True);
Assert.That(system.AreAccessTagsAllowed(Array.Empty<ProtoId<AccessLevelPrototype>>(), reader), Is.True);
});
// test deny
system.AddDenyTag(reader, "A");
Assert.Multiple(() =>
{
Add door electronics access configuration menu (#17778) * Add door electronics configuration menu * Use file-scoped namespaces Signed-off-by: c4llv07e <kseandi@gmail.com> * Open door electronics configuration menu only with network configurator Signed-off-by: c4llv07e <kseandi@gmail.com> * Doors will now try to move their AccessReaderComponent to their door electronics when the map is initialized Signed-off-by: c4llv07e <kseandi@gmail.com> * Make the access list in the id card computer a separate control Signed-off-by: c4llv07e <kseandi@gmail.com> * Fix merge conflict Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove DoorElectronics tag Signed-off-by: c4llv07e <kseandi@gmail.com> * Integrate doors with #17927 Signed-off-by: c4llv07e <kseandi@gmail.com> * Move door electornics ui stuff to the right place Signed-off-by: c4llv07e <kseandi@gmail.com> * Some review fixes Signed-off-by: c4llv07e <kseandi@gmail.com> * More fixes Signed-off-by: c4llv07e <kseandi@gmail.com> * review fix Signed-off-by: c4llv07e <kseandi@gmail.com> * move all accesses from airlock prototypes to door electronics Signed-off-by: c4llv07e <kseandi@gmail.com> * rework door electronics config access list Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove Linq from the door electronics user interface * [WIP] Add EntityWhitelist to the activatable ui component Signed-off-by: c4llv07e <kseandi@gmail.com> * Better interaction system Signed-off-by: c4llv07e <kseandi@gmail.com> * Refactor Signed-off-by: c4llv07e <kseandi@gmail.com> * Fix some door electronics not working without AccessReaderComponent Signed-off-by: c4llv07e <kseandi@gmail.com> * Move AccessReaderComponent update code to the AccessReaderSystem Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove unnecesary newlines in the door access prototypes Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove unused variables in access level control Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove unnecessary method from the door electronics configuration menu Signed-off-by: c4llv07e <kseandi@gmail.com> * [WIP] change access type from string to ProtoId<AccessLevelPrototype> Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove unused methods Signed-off-by: c4llv07e <kseandi@gmail.com> * Newline fix Signed-off-by: c4llv07e <kseandi@gmail.com> * Restored to a functional state Signed-off-by: c4llv07e <kseandi@gmail.com> * Fix access configurator not working with door electronics AccessReaderComponent Signed-off-by: c4llv07e <kseandi@gmail.com> * Replace all string access fields with ProtoId Signed-off-by: c4llv07e <kseandi@gmail.com> * move access level control initialization into Populate method Signed-off-by: c4llv07e <kseandi@gmail.com> * Review --------- Signed-off-by: c4llv07e <kseandi@gmail.com> Co-authored-by: metalgearsloth <comedian_vs_clown@hotmail.com>
2024-04-01 09:06:13 +03:00
Assert.That(system.AreAccessTagsAllowed(new List<ProtoId<AccessLevelPrototype>> { "Foo" }, reader), Is.True);
Assert.That(system.AreAccessTagsAllowed(new List<ProtoId<AccessLevelPrototype>> { "A" }, reader), Is.False);
Assert.That(system.AreAccessTagsAllowed(new List<ProtoId<AccessLevelPrototype>> { "A", "Foo" }, reader), Is.False);
Assert.That(system.AreAccessTagsAllowed(Array.Empty<ProtoId<AccessLevelPrototype>>(), reader), Is.True);
});
system.ClearDenyTags(reader);
// test one list
system.AddAccess(reader, "A");
Assert.Multiple(() =>
{
Add door electronics access configuration menu (#17778) * Add door electronics configuration menu * Use file-scoped namespaces Signed-off-by: c4llv07e <kseandi@gmail.com> * Open door electronics configuration menu only with network configurator Signed-off-by: c4llv07e <kseandi@gmail.com> * Doors will now try to move their AccessReaderComponent to their door electronics when the map is initialized Signed-off-by: c4llv07e <kseandi@gmail.com> * Make the access list in the id card computer a separate control Signed-off-by: c4llv07e <kseandi@gmail.com> * Fix merge conflict Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove DoorElectronics tag Signed-off-by: c4llv07e <kseandi@gmail.com> * Integrate doors with #17927 Signed-off-by: c4llv07e <kseandi@gmail.com> * Move door electornics ui stuff to the right place Signed-off-by: c4llv07e <kseandi@gmail.com> * Some review fixes Signed-off-by: c4llv07e <kseandi@gmail.com> * More fixes Signed-off-by: c4llv07e <kseandi@gmail.com> * review fix Signed-off-by: c4llv07e <kseandi@gmail.com> * move all accesses from airlock prototypes to door electronics Signed-off-by: c4llv07e <kseandi@gmail.com> * rework door electronics config access list Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove Linq from the door electronics user interface * [WIP] Add EntityWhitelist to the activatable ui component Signed-off-by: c4llv07e <kseandi@gmail.com> * Better interaction system Signed-off-by: c4llv07e <kseandi@gmail.com> * Refactor Signed-off-by: c4llv07e <kseandi@gmail.com> * Fix some door electronics not working without AccessReaderComponent Signed-off-by: c4llv07e <kseandi@gmail.com> * Move AccessReaderComponent update code to the AccessReaderSystem Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove unnecesary newlines in the door access prototypes Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove unused variables in access level control Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove unnecessary method from the door electronics configuration menu Signed-off-by: c4llv07e <kseandi@gmail.com> * [WIP] change access type from string to ProtoId<AccessLevelPrototype> Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove unused methods Signed-off-by: c4llv07e <kseandi@gmail.com> * Newline fix Signed-off-by: c4llv07e <kseandi@gmail.com> * Restored to a functional state Signed-off-by: c4llv07e <kseandi@gmail.com> * Fix access configurator not working with door electronics AccessReaderComponent Signed-off-by: c4llv07e <kseandi@gmail.com> * Replace all string access fields with ProtoId Signed-off-by: c4llv07e <kseandi@gmail.com> * move access level control initialization into Populate method Signed-off-by: c4llv07e <kseandi@gmail.com> * Review --------- Signed-off-by: c4llv07e <kseandi@gmail.com> Co-authored-by: metalgearsloth <comedian_vs_clown@hotmail.com>
2024-04-01 09:06:13 +03:00
Assert.That(system.AreAccessTagsAllowed(new List<ProtoId<AccessLevelPrototype>> { "A" }, reader), Is.True);
Assert.That(system.AreAccessTagsAllowed(new List<ProtoId<AccessLevelPrototype>> { "B" }, reader), Is.False);
Assert.That(system.AreAccessTagsAllowed(new List<ProtoId<AccessLevelPrototype>> { "A", "B" }, reader), Is.True);
Assert.That(system.AreAccessTagsAllowed(Array.Empty<ProtoId<AccessLevelPrototype>>(), reader), Is.False);
});
system.ClearAccesses(reader);
// test one list - two items
system.AddAccess(reader, new HashSet<ProtoId<AccessLevelPrototype>> { "A", "B" });
Assert.Multiple(() =>
{
Add door electronics access configuration menu (#17778) * Add door electronics configuration menu * Use file-scoped namespaces Signed-off-by: c4llv07e <kseandi@gmail.com> * Open door electronics configuration menu only with network configurator Signed-off-by: c4llv07e <kseandi@gmail.com> * Doors will now try to move their AccessReaderComponent to their door electronics when the map is initialized Signed-off-by: c4llv07e <kseandi@gmail.com> * Make the access list in the id card computer a separate control Signed-off-by: c4llv07e <kseandi@gmail.com> * Fix merge conflict Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove DoorElectronics tag Signed-off-by: c4llv07e <kseandi@gmail.com> * Integrate doors with #17927 Signed-off-by: c4llv07e <kseandi@gmail.com> * Move door electornics ui stuff to the right place Signed-off-by: c4llv07e <kseandi@gmail.com> * Some review fixes Signed-off-by: c4llv07e <kseandi@gmail.com> * More fixes Signed-off-by: c4llv07e <kseandi@gmail.com> * review fix Signed-off-by: c4llv07e <kseandi@gmail.com> * move all accesses from airlock prototypes to door electronics Signed-off-by: c4llv07e <kseandi@gmail.com> * rework door electronics config access list Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove Linq from the door electronics user interface * [WIP] Add EntityWhitelist to the activatable ui component Signed-off-by: c4llv07e <kseandi@gmail.com> * Better interaction system Signed-off-by: c4llv07e <kseandi@gmail.com> * Refactor Signed-off-by: c4llv07e <kseandi@gmail.com> * Fix some door electronics not working without AccessReaderComponent Signed-off-by: c4llv07e <kseandi@gmail.com> * Move AccessReaderComponent update code to the AccessReaderSystem Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove unnecesary newlines in the door access prototypes Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove unused variables in access level control Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove unnecessary method from the door electronics configuration menu Signed-off-by: c4llv07e <kseandi@gmail.com> * [WIP] change access type from string to ProtoId<AccessLevelPrototype> Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove unused methods Signed-off-by: c4llv07e <kseandi@gmail.com> * Newline fix Signed-off-by: c4llv07e <kseandi@gmail.com> * Restored to a functional state Signed-off-by: c4llv07e <kseandi@gmail.com> * Fix access configurator not working with door electronics AccessReaderComponent Signed-off-by: c4llv07e <kseandi@gmail.com> * Replace all string access fields with ProtoId Signed-off-by: c4llv07e <kseandi@gmail.com> * move access level control initialization into Populate method Signed-off-by: c4llv07e <kseandi@gmail.com> * Review --------- Signed-off-by: c4llv07e <kseandi@gmail.com> Co-authored-by: metalgearsloth <comedian_vs_clown@hotmail.com>
2024-04-01 09:06:13 +03:00
Assert.That(system.AreAccessTagsAllowed(new List<ProtoId<AccessLevelPrototype>> { "A" }, reader), Is.False);
Assert.That(system.AreAccessTagsAllowed(new List<ProtoId<AccessLevelPrototype>> { "B" }, reader), Is.False);
Assert.That(system.AreAccessTagsAllowed(new List<ProtoId<AccessLevelPrototype>> { "A", "B" }, reader), Is.True);
Assert.That(system.AreAccessTagsAllowed(Array.Empty<ProtoId<AccessLevelPrototype>>(), reader), Is.False);
});
system.ClearAccesses(reader);
// test two list
var accesses = new List<HashSet<ProtoId<AccessLevelPrototype>>>() {
new HashSet<ProtoId<AccessLevelPrototype>> () { "A" },
new HashSet<ProtoId<AccessLevelPrototype>> () { "B", "C" }
};
system.AddAccesses(reader, accesses);
Assert.Multiple(() =>
{
Add door electronics access configuration menu (#17778) * Add door electronics configuration menu * Use file-scoped namespaces Signed-off-by: c4llv07e <kseandi@gmail.com> * Open door electronics configuration menu only with network configurator Signed-off-by: c4llv07e <kseandi@gmail.com> * Doors will now try to move their AccessReaderComponent to their door electronics when the map is initialized Signed-off-by: c4llv07e <kseandi@gmail.com> * Make the access list in the id card computer a separate control Signed-off-by: c4llv07e <kseandi@gmail.com> * Fix merge conflict Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove DoorElectronics tag Signed-off-by: c4llv07e <kseandi@gmail.com> * Integrate doors with #17927 Signed-off-by: c4llv07e <kseandi@gmail.com> * Move door electornics ui stuff to the right place Signed-off-by: c4llv07e <kseandi@gmail.com> * Some review fixes Signed-off-by: c4llv07e <kseandi@gmail.com> * More fixes Signed-off-by: c4llv07e <kseandi@gmail.com> * review fix Signed-off-by: c4llv07e <kseandi@gmail.com> * move all accesses from airlock prototypes to door electronics Signed-off-by: c4llv07e <kseandi@gmail.com> * rework door electronics config access list Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove Linq from the door electronics user interface * [WIP] Add EntityWhitelist to the activatable ui component Signed-off-by: c4llv07e <kseandi@gmail.com> * Better interaction system Signed-off-by: c4llv07e <kseandi@gmail.com> * Refactor Signed-off-by: c4llv07e <kseandi@gmail.com> * Fix some door electronics not working without AccessReaderComponent Signed-off-by: c4llv07e <kseandi@gmail.com> * Move AccessReaderComponent update code to the AccessReaderSystem Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove unnecesary newlines in the door access prototypes Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove unused variables in access level control Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove unnecessary method from the door electronics configuration menu Signed-off-by: c4llv07e <kseandi@gmail.com> * [WIP] change access type from string to ProtoId<AccessLevelPrototype> Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove unused methods Signed-off-by: c4llv07e <kseandi@gmail.com> * Newline fix Signed-off-by: c4llv07e <kseandi@gmail.com> * Restored to a functional state Signed-off-by: c4llv07e <kseandi@gmail.com> * Fix access configurator not working with door electronics AccessReaderComponent Signed-off-by: c4llv07e <kseandi@gmail.com> * Replace all string access fields with ProtoId Signed-off-by: c4llv07e <kseandi@gmail.com> * move access level control initialization into Populate method Signed-off-by: c4llv07e <kseandi@gmail.com> * Review --------- Signed-off-by: c4llv07e <kseandi@gmail.com> Co-authored-by: metalgearsloth <comedian_vs_clown@hotmail.com>
2024-04-01 09:06:13 +03:00
Assert.That(system.AreAccessTagsAllowed(new List<ProtoId<AccessLevelPrototype>> { "A" }, reader), Is.True);
Assert.That(system.AreAccessTagsAllowed(new List<ProtoId<AccessLevelPrototype>> { "B" }, reader), Is.False);
Assert.That(system.AreAccessTagsAllowed(new List<ProtoId<AccessLevelPrototype>> { "A", "B" }, reader), Is.True);
Assert.That(system.AreAccessTagsAllowed(new List<ProtoId<AccessLevelPrototype>> { "C", "B" }, reader), Is.True);
Assert.That(system.AreAccessTagsAllowed(new List<ProtoId<AccessLevelPrototype>> { "C", "B", "A" }, reader), Is.True);
Assert.That(system.AreAccessTagsAllowed(Array.Empty<ProtoId<AccessLevelPrototype>>(), reader), Is.False);
});
system.ClearAccesses(reader);
// test deny list
system.AddAccess(reader, new HashSet<ProtoId<AccessLevelPrototype>> { "A" });
system.AddDenyTag(reader, "B");
Assert.Multiple(() =>
{
Add door electronics access configuration menu (#17778) * Add door electronics configuration menu * Use file-scoped namespaces Signed-off-by: c4llv07e <kseandi@gmail.com> * Open door electronics configuration menu only with network configurator Signed-off-by: c4llv07e <kseandi@gmail.com> * Doors will now try to move their AccessReaderComponent to their door electronics when the map is initialized Signed-off-by: c4llv07e <kseandi@gmail.com> * Make the access list in the id card computer a separate control Signed-off-by: c4llv07e <kseandi@gmail.com> * Fix merge conflict Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove DoorElectronics tag Signed-off-by: c4llv07e <kseandi@gmail.com> * Integrate doors with #17927 Signed-off-by: c4llv07e <kseandi@gmail.com> * Move door electornics ui stuff to the right place Signed-off-by: c4llv07e <kseandi@gmail.com> * Some review fixes Signed-off-by: c4llv07e <kseandi@gmail.com> * More fixes Signed-off-by: c4llv07e <kseandi@gmail.com> * review fix Signed-off-by: c4llv07e <kseandi@gmail.com> * move all accesses from airlock prototypes to door electronics Signed-off-by: c4llv07e <kseandi@gmail.com> * rework door electronics config access list Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove Linq from the door electronics user interface * [WIP] Add EntityWhitelist to the activatable ui component Signed-off-by: c4llv07e <kseandi@gmail.com> * Better interaction system Signed-off-by: c4llv07e <kseandi@gmail.com> * Refactor Signed-off-by: c4llv07e <kseandi@gmail.com> * Fix some door electronics not working without AccessReaderComponent Signed-off-by: c4llv07e <kseandi@gmail.com> * Move AccessReaderComponent update code to the AccessReaderSystem Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove unnecesary newlines in the door access prototypes Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove unused variables in access level control Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove unnecessary method from the door electronics configuration menu Signed-off-by: c4llv07e <kseandi@gmail.com> * [WIP] change access type from string to ProtoId<AccessLevelPrototype> Signed-off-by: c4llv07e <kseandi@gmail.com> * Remove unused methods Signed-off-by: c4llv07e <kseandi@gmail.com> * Newline fix Signed-off-by: c4llv07e <kseandi@gmail.com> * Restored to a functional state Signed-off-by: c4llv07e <kseandi@gmail.com> * Fix access configurator not working with door electronics AccessReaderComponent Signed-off-by: c4llv07e <kseandi@gmail.com> * Replace all string access fields with ProtoId Signed-off-by: c4llv07e <kseandi@gmail.com> * move access level control initialization into Populate method Signed-off-by: c4llv07e <kseandi@gmail.com> * Review --------- Signed-off-by: c4llv07e <kseandi@gmail.com> Co-authored-by: metalgearsloth <comedian_vs_clown@hotmail.com>
2024-04-01 09:06:13 +03:00
Assert.That(system.AreAccessTagsAllowed(new List<ProtoId<AccessLevelPrototype>> { "A" }, reader), Is.True);
Assert.That(system.AreAccessTagsAllowed(new List<ProtoId<AccessLevelPrototype>> { "B" }, reader), Is.False);
Assert.That(system.AreAccessTagsAllowed(new List<ProtoId<AccessLevelPrototype>> { "A", "B" }, reader), Is.False);
Assert.That(system.AreAccessTagsAllowed(Array.Empty<ProtoId<AccessLevelPrototype>>(), reader), Is.False);
});
system.ClearAccesses(reader);
system.ClearDenyTags(reader);
});
2023-08-25 02:56:51 +02:00
await pair.CleanReturnAsync();
}
}
}